Proceedings of the JFPS International Symposium on Fluid Power
Online ISSN : 2185-6303
ISSN-L : 2185-6303
VISUALIZATION AND DETECTION OF CAVITATION IN V-SHAPED GROOVE TYPE VALVE PLATE OF AN AXIAL PISTON PUMP
Kazumi ItoKiyoshi InoueKeiji Saito
著者情報
ジャーナル フリー

1996 年 1996 巻 3 号 p. 67-72

詳細
抄録
This paper deals with the cavitation occurrence at V-shaped groove of valve plate in an axial piston pump. The cavitating jet from V-shaped groove was visualized using high speed video camera system. The detection of cavitation was also attempted by using AE (acoustic emission) sensors. The results obtained from the tests are as follows:
1) Caviation inception/desinence at V-shaped groove was visualized under actual pump operation at the operating pressure of 3MPa.
2) It was proved that cavitation inception and desinence are detectable by AE sensors.
著者関連情報
© The Japan Fluid Power System Society
前の記事 次の記事
feedback