日本原子力学会誌
Online ISSN : 2186-5256
Print ISSN : 0004-7120
ISSN-L : 0004-7120
武蔵工大炉医療用照射場の中性子ビーム設計
松本 哲男
著者情報
ジャーナル フリー

1996 年 38 巻 8 号 p. 673-682

詳細
抄録

Design studies were carried out for the Musashi reactor (TRIGA-II, 100kW) with a view to generating epithermal and thermal neutron beams applicable to boron neutron capture therapy (BNCT). By Monte Carlo calculations, the thermal neutron beam intensity 1.1×109n/cmcm2·s and the epithermal neutron beam intensity 4.1×108n/cmcm2·s at the operation power of 100kW have been obtained at the irradiation ports in the thermal and thermalizing columns, respectively. These beams are little adulterated with fast neutrons and gamma-rays, and are relatively forward-directed. Depth-dose calculations in a tissue phantom showed that above thermal and epithermal neutron beams would be useful to treat superficial (-4cm) and deeper (-6.5cm) tumors, respectively. The full-dose treatment time is estimated about 2.5h. These neutron beam designs suggest how TRIGA reactors could be modified for BNCT, and the produced neutron beams, if built into the Musashi reactor, will significantly increase the chance of success of BNCT in Japan.

著者関連情報
© by the Atomic Energy Society of Japan
前の記事 次の記事
feedback