Resently, It is essentially necessary to obtain the hydraulic parameters of ground water in deep geological environment in order to contribute on the establisment to modelling of regional ground water flow.
However, in-situ test method in the low permeable zone have not been developed. Hence we developed "New PNC Aquifer Test Method" with a single borehole and nonsteady state theory.
This measurmentu nit was developedt o settlment four problem as follows,1 ) To prevent hydraulic destruction,2) Improvement of operating efficiency,3) To measure a pore water pressure in low permeability,4) To measure the coefficient of permeability in low permeable rock bed.
When to make in-situ experiment, w e got a good result.
The minimumc oefficiento f permeability on in-s i tu experiment was 8.5×10-9 c m/sec and the measurement was over within 6 hours