日本気管食道科学会会報
Online ISSN : 1880-6848
Print ISSN : 0029-0645
ISSN-L : 0029-0645
シリコンブロック挿入18年後の喉頭病理所見
狩野 章太郎深谷 卓田山 二朗手塚 克彦三富 夏彦新美 成二
著者情報
ジャーナル フリー

1999 年 50 巻 6 号 p. 620-624

詳細
抄録

Thyroplasty type I is one of various surgical treatments for glottic insufficiency following unilateral recurrent nerve paralysis. However, the choice of materials for the prosthesis inserted into the thyroid cartilage is controversial with regard to stability and safety. We experienced a case of laryngeal palsy caused by syringomyelobulbia. Thyroplasty type I was performed with a silicone block 18 years ago to prevent aspiration pneumonia, but in accordance with progress of the laryngeal palsy, the patient developed severe pneumonia. We performed a total laryngectomy for the improvement of his dysphagia, and conducted a histopathological study of the larynx with the silicone prosthesis. We found slight fibrinogenesis around the silicone block, however, foreign body giant cells, inflammatory cells, or absorption of silicone were not observed. We tentatively concluded that these findings show the stability and safety of silicone as a prosthesis for thyroplasty type I.