電気関係学会九州支部連合大会講演論文集
2019年度電気・情報関係学会九州支部連合大会(第72回連合大会)講演論文集
セッションID: 04-2A-08
会議情報

コヒーレントエリアに基づく電力系統の脆弱性評価のための同期位相計測装置の最適配置
*Matsukawa YoshiakiWatanabe Masayuki
著者情報
会議録・要旨集 フリー

詳細
抄録

Phasor Measurement Unit (PMU) is the important component of Wide Area Measurement System as the measurement device for constant monitoring of power systems. However, the PMU cost is still expensive, thus the location must be optimally selected. This paper studies on the optimal PMU placement for the dynamic vulnerability assessment evaluated by the center-of-inertia based frequency in electric fast coherent areas determined by hierarchical clustering. The statistical simulation provides the optimal PMU placement to enhance the system security level with suppressing the PMU cost.

著者関連情報
© 2019 電気・情報関係学会九州支部連合大会委員会