JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Online ISSN : 1881-1299
Print ISSN : 0021-9592
Original Papers
Mean Drop Size and Size Distribution in Rotating Disc Contactor Used for Reversed Micellar Extraction of Proteins
Jihong TongShintaro Furusaki
著者情報
ジャーナル フリー

1995 年 28 巻 5 号 p. 582-589

詳細
抄録

As a study on the extraction apparatus for separation and purification of proteins and other molecules using reversed micellar systems, the mean drop diameter and drop size distribution of the reversed micellar dispersed phase have been investigated using a rotating disc contactor (RDC) of 38 mm diameter. The Sauter mean diameter was correlated with the Reynolds number, Re, the Weber number, We and the density ratio of the two phases, and the correlation was found to be in good agreement with the experimental data within 15%. The data obtained from the experimental runs and the correlation are compared with those of other authors for liquid-liquid systems without surfactants. The Mugele-Evans distribution function has proved to be the best of the four functions of Mugele-Evans, log-normal, normal and Weibull distribution functions for representing the experimental drop size distribution data. Correlations for the distribution function parameters by means of the Sauter mean diameter obtained in this work can be used to estimate drop size distribution of the reversed micellar systems.

著者関連情報
© 1995 The Society of Chemical Engineers, Japan
前の記事 次の記事
feedback
Top