Journal of the Ceramic Society of Japan (日本セラミックス協会学術論文誌)
Online ISSN : 1882-1022
Print ISSN : 0914-5400
ISSN-L : 0914-5400
テクニカルレポート
加熱気化/ICP-MS におけるマトリックス成分補正方法の提案とSBT 薄膜中微量金属への適用
光亦 博志森 俊雄
著者情報
ジャーナル フリー

2006 年 114 巻 1332 号 p. 705-708

詳細
抄録
We established a simple electrothermal vaporization (ETV)/inductively coupled plasma mass spectrometry (ICP-MS) technique without separating analyte elements from a matrix to determine trace metallic impurities of eight elements (Na, Mg, Al, Cr, Mn, Fe, Ni, and Cu) in a Y-1 (strontium (Sr)-bismuth (Bi)-tantalum (Ta)-oxygen (O)) thin film for semiconductor ferroelectric random-access memories. To improve the linearity of each calibration curve (20 pg ml-1-10 ng ml-1), we added the same concentration of Sr, Bi and Ta to a mixed standard solution as those in the sample solution as a mixed modifier. The recovery percentages obtained by adding 1 ng ml-1 of each element to the sample solution were between Al (90%)-Cr (105%). The detection limit (3σ) was 1.9×1010 (Mn)-1.3×1012 (Al) atoms cm-2 for a Y-1 thin film with a diameter of 150 mm. The proposed method was applied to the real samples to determine the eight metallic elements (1011-1013 atoms cm-2).
著者関連情報
© 2006 The Ceramic Society of Japan
前の記事 次の記事