Journal of the Ceramic Society of Japan (日本セラミックス協会学術論文誌)
Online ISSN : 1882-1022
Print ISSN : 0914-5400
ISSN-L : 0914-5400
テクニカルレポート
微小圧子押込み試験 (IF) 法で求めた窒化ケイ素の破壊靭性に及ぼすクラック長の測定方法の影響
宮崎 広行日向 秀樹平尾 喜代司大司 達樹
著者情報
ジャーナル フリー

2006 年 114 巻 1333 号 p. 787-790

詳細
抄録
The dependence of fracture toughness estimated by indentation fracture technique on measuring method was studied using several Si3N4 samples with various microstructures. The crack length at the indentation load of 19.6 N was measured by optical microscopy and SEM and fracture toughness was calculated for each case. The consistency of results between the two methods was obtained within the accuracy of the data for any microstructure. It was revealed that in the case of silicon nitrides indented at low load, the IF technique was not so equipment sensitive, indicating that the accuracy of IF method by OM is not necessarily inferior to one by the SEM. It was considered that the IF method with optical microscopy would become useful test for fracture toughness if the testing procedure is properly controlled to minimize the source of the measuring error.
著者関連情報
© 2006 The Ceramic Society of Japan
前の記事 次の記事
feedback
Top