大日本窯業協會雑誌
Online ISSN : 1884-2119
Print ISSN : 0366-9998
ISSN-L : 0366-9998
熔融石英の粘度の測定
犬塚 英夫
著者情報
ジャーナル フリー

1939 年 47 巻 558 号 p. 292-294

詳細
抄録

This paper dealt with the viscosity measurement of transparent fused silica by S. English's method.
The elongation caused by weight hanged at the end of the specimen is measured by cathetometer as illustrated.
The viscosity is caluculated from following formula.
The softning temperature of the specimen is about 1150°C.
Duaring the investigation, minute crystals are observed on the surface of the specimen. This is crystobalite devitrified from fused silica.
By devitrification, elongation of specimen decressed with the lapse of time.

著者関連情報
© The Ceramic Society of Japan
前の記事 次の記事