Corrosion Engineering
Online ISSN : 1881-9664
Print ISSN : 0917-0480
ISSN-L : 0917-0480
-A Rapid Communication Note of the 61th Japan Conference on Materials Environments-
Change of pH of Inside the Crevice with Time During Crevice Corrosion Initiation and Growth Step of a Duplex Stainless Steel
Nobuaki ItoRyotaro YamamotoJun'ichi Sakai
Author information
JOURNAL FREE ACCESS

2015 Volume 64 Issue 5 Pages 193-196

Details
Abstract
The objective in this study was to clarify the change of pH with time inside crevice in potentiostatic crevice corrosion test.Sensing plate to discoloration by the change of pH was made. The crevice corrosion of a duplex stainless steel in potentiostatic crevice corrosion test using a sensing plate was in situ observation. The change of pH with time inside crevice was measured by discoloration of the coating agent of the sensing plate. Crevice corrosion of duplex stainless steel occurred at the point where pH is lowered locally. And, it was found that pH of crevice corrosion tip was below the depassivation pH of both phases.
Content from these authors
© 2015 Japan Society of Corrosion Engineering
Previous article Next article
feedback