低ノイズ単段パルス管冷凍機の開発
藤本 修二平塚 善勝森下 弘之永石 竜起
著者情報
ジャーナル フリー

2004 年 39 巻 7 号 p. 322-327

詳細
抄録

A low-noise, pulse-tube cryocooler has been developed. It is suitable for cooling variable semiconductor or superconducting devices. The cryocooler's electro-magnetic noise and inclination characteristics are improved, and the cooling capacity is 4.9 W at 77 K with an input power of 800 W. The minimum temperature was less than 49 K. The cooling performance at 77 K was within 5% degradation for all orientations. The low-noise pulse-tube cryocooler was installed in a cryostat designed for a high-Tc SQUID sensor. The electro-magnetic noise was measured by the magnetometer-type SQUID sensor cooled in the cryostat. The noise level was influenced by the direction of the sensor. When the sensor was parallel to the cryocooler cylinder, the white noise was about 300 fT/√Hz and the cyclic noise produced by the cryocooler's magnetic material or mechanical vibration was not observed. When the sensor was vertical to the cylinder, the white noise was about 2 pT/√Hz and the cyclic noise was about 10 pT rms. A real-time magnetocardiography was successfully measured using a high-Tc SQUID magnetometer cooled by the pulse-tube cryocooler. The signal-to-noise ratio was better than the conventional cryocooling system.

著者関連情報
© 2004 公益社団法人 低温工学・超電導学会 (旧 社団法人 低温工学協会)