JT-60SAマグネット及びヘリウム冷凍システム統合試験運転
―ヘリウム冷凍システム運転結果―
濱田 一弥 福井 良磨河野 勝巳大西 祥広本田 敦市毛 尚志佐藤 稔村上 陽之薄井 勝富柏 好敏櫻井 嶺太阿部 太一大都 起一Sam DAVISGuy PHILLIPSManfred WANNERTomarchio VALERIOLouis ZANI阿部 功Christine HOAFrederic MICHIEL
著者情報
ジャーナル フリー

2024 年 59 巻 5 号 p. 289-296

詳細
抄録

JT-60SA cryogenic system comprises a main refrigerator cold box, auxiliary cold box, warm helium compressor, control system, and utility system (cooling water and instrumentation air). The total equivalent refrigerator power is 9.5 kW at 4.5 K. The cryogenic system supplied 4.4 K supercritical helium to the magnet system, 50 K pressurized helium gas to high-temperature superconducting current lead, and 80 K pressurized helium gas to the thermal shield. Before cooldown, cryostat helium leak testing and helium gas purification were performed. It took approximately 41 days to cool the magnet system from room temperature to superconducting transition temperature. During operation, the refrigerator was stopped three times because of electrical grounding problems and incorrect control parameter values in the cold rotation machine control system. Except for problems, the cryogenic system was steadily operated. This paper describes the cryogenic system operation results during cooldown and magnet operation.