低温工学
Online ISSN : 1880-0408
Print ISSN : 0389-2441
ISSN-L : 0389-2441
Bi系バルク超電導体における交流通電時の交流損失
岩熊 成卓川浪 精一和久田 毅式町 浩二木稲 博之船木 和夫竹尾 正勝山藤 馨田中 靖三三村 正直植田 和雄樋上 久彰
著者情報
ジャーナル フリー

1994 年 29 巻 4 号 p. 140-149

詳細
抄録

It is shown that the observed value of the AC loss of a cylindrical BSCCO bulk superconductor with the diameter of 9.6mm, carrying the AC transport current with the frequency of 60Hz, deviates noticeably from the theoretical values estimated from the critical state model. It is clarified that this deviation results from the fact that the internal distribution of flux density, B(r), is quite different from that predicted by the critical state model, when the AC transport current with the frequency, f, of 60Hz is applied to the sample with a large diameter, R, and with a low n-value. This conclusion is based on the numerically simulated results of B(r) obtained by solving the Maxwell equations using the observed Jc=Jc(B) and E(J)=E(0)(J/Jc)n characteristics for the DC electric field, E, the DC transport current density, J, and the DC critical current density, Jc, determined by the criterion of 0.1μV/cm. Finally, a general numerical chart of the AC loss against fR2Jc is presented for the various n-values, for the convenience of the design of the high-Tc current leads.

著者関連情報
© 社団法人低温工学協会
前の記事 次の記事
feedback
Top