鋳造工学
Online ISSN : 2185-5374
Print ISSN : 1342-0429
ISSN-L : 1342-0429
研究論文
注湯機の傾動軸迅速昇降装置による流量最適化の試み
松田 政夫頃安 貞利
著者情報
ジャーナル フリー

1997 年 69 巻 3 号 p. 207-212

詳細
抄録
  The flow of water from the pouring equipment with a quick up-down mechanism of the tiltcenter was studied experimentally. When the quick up-down mechanism was used, the flow rate at the start of pouring rose up more rapidly and that at the end of pouring cut off more rapidly than when this mechanism was not used. Various patterns of the change of flow rate at the intermediate region of pouring can be obtained by adjusting appropriate values of the up-down strokes of the tilt-center and the tilting speed of the pouring machine.
著者関連情報
© 1997 公益社団法人 日本鋳造工学会
前の記事 次の記事