2014 年 6 巻 1 号 p. 9-16
In this paper, the performance of vaned diffusers on low specific speed centrifugal compressors, was investigated experimentally and analytically. There is a problem of non-uniform distribution of the flow at impeller exit, as a factor to deteriorate the performance of the diffuser. This problem appears remarkably on the low specific speed type, because the blade height is relatively small and the flow inclines toward circumferential direction. The experiment was carried out with 2nd stage compressor of two-stage centrifugal type, focusing on the effect of number of diffuser vanes, vaneless ratio and throat area. Furthermore, unsteady fluid analysis was carried out by using Non Linear Harmonic method in order to understand about the phenomenon associated with the problem of non-uniform distribution of the flow.