Journal of Hard Tissue Biology
Online ISSN : 1880-828X
Print ISSN : 1341-7649
ISSN-L : 1341-7649
Original
The Constant Extension Rate Tensile of AZ31B Magnesium Alloy with Si-contained Coating in Dynamic Simulated Body Fluid
Qiang WangYoshinori NakamuraIkuro KatoHatsuhiko MaedaLili TanKe Yang
著者情報
ジャーナル フリー

2013 年 22 巻 2 号 p. 177-182

詳細
抄録
The tensile fracture characteristics of AZ31B magnesium alloy with Si-contained coating was studied using a constant extension rate tensile in dynamic Hank’s solution. The study showed that the fracture characteristics of the uncoated and coated AZ31B magnesium were different. The uncoated alloy exhibited predominant intergranular cracks while the coated revealed mixed intergranular and transgranular mode failure. The mechanical integrity of the coated AZ31B magnesium alloy was improved compared with the uncoated.
著者関連情報
© 2013 by The Hard Tissue Biology Network Association(JHTBNet)
前の記事 次の記事
feedback
Top