日本エネルギー学会誌
Online ISSN : 1882-6121
Print ISSN : 0916-8753
ISSN-L : 0916-8753
論文
1.5MWth炉灰付着試験での熱流束低下挙動に基づく,石炭焚きボイラでのスートブロワ頻度に関する検討
下郡 三紀嶺 聡彦大谷津 紀之寶山 登松村 幸彦
著者情報
ジャーナル フリー

2012 年 91 巻 5 号 p. 417-424

詳細
抄録
To obtain practical knowledge in operating soot-blowers without ash related problems, a series of slagging tests have been conducted at 1.5 MWth pilot plant and the rates of decreasing heat fluxes through the test probe simulating the water-wall have been determined. In this study, initial heat flux, this heat flux decreasing rate, and the heat flux at which decreasing heat flux rate is reduced are employed to predict the soot blowing time. A simple equation is obtained for predicting the soot blowing timing. Discussion is made on the derivation of the equation, and it is expected that the derived equation holds for any furnace.
著者関連情報
© 2012 一般社団法人 日本エネルギー学会
前の記事
feedback
Top