日本エネルギー学会誌
Online ISSN : 1882-6121
Print ISSN : 0916-8753
ISSN-L : 0916-8753
高温脱塵装置 (CTF) の圧損予測
笹津 浩司三沢 信博清水 正明阿部 力也
著者情報
ジャーナル フリー

2000 年 79 巻 8 号 p. 840-849

詳細
抄録
he pressure drop across CTF (Ceramic Tube Filter) which is installed at Wakamatsu 71MW PFBC combined cycle power plant, is one of key parameters for both plant operation and performance. The pressure drop was attempted to predict, based on the data obtained with/without pre-cleaning cyclones installed at the upstream of CTF in Phasel and Phase2, respectively. The pressure drop consisted of two components of base line for filter itself and increasing ones with accumulated ash.
The base line pressure drop soon after pulse cleaning (ΔPbase) was estimated based on D'Arcy law using pre-measured L/K (thickness/permeability) values, while the rate of increasing pressure drop with accumulated ash between pulse cleaning interval (dΔPc/dt) was estimated by Kozeny-Carman equation using ash analysis. Thus, the maximum pressure drop across filters was predicted successfully in both with/without pre-cleaning system from the respective linear correlation. The reason why ΔPbase was much higher without pre-cleaning system (Phase2) is discussed in terms of both characterization of permanent ash layer and behavior of fine ash in CTF during pulse cleaning.
著者関連情報
© 社団法人日本エネルギー学会
前の記事 次の記事