照明学会誌
Online ISSN : 1349-838X
Print ISSN : 0019-2341
ISSN-L : 0019-2341

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

ヘッドライトを用いた耳鏡検査における耳鏡の集光性能評価および集光最適化設計
松本 光広
著者情報
ジャーナル フリー 早期公開

論文ID: 190000584

この記事には本公開記事があります。
詳細
抄録

We evaluated the performance of light focus in an existing otoscope with a headlight employing an LED source. The mechanism of the otoscope was shown, and a coordinate system was set in the otoscope to evaluate the light-focusing performance. Experimental equipment based on the set coordinate system was built using the existing otoscope and headlight. We demonstrated experimental methods for measuring illuminance at the narrow mouth in the otoscope using the built experimental equipment. In the experiments conducted using the experimental methods, the performance of light focus in the existing otoscope was evaluated by measuring the illuminance. The optimal new otoscope for focusing light was designed using a headlight employing the LED source. The otoscope was built using the results obtained by the designs. We evaluated the performance of light focus in the designed otoscope with the otoscopes we built. The experimental equipment was built with the constructed otoscope and the headlight. We demonstrated experimental methods for measuring illuminance at the narrow mouth in the otoscope using the built experimental equipment. In the experiments conducted using the experimental methods, the performance of light focus in the designed otoscope was evaluated by the measured illuminance.

著者関連情報
© 2020 一般社団法人 照明学会
feedback
Top