1984 Volume 48 Issue 5 Pages 91-96
As to the study on fire preventive function of trees, this paper shows the critical tempreature to auto-ignition of leaves. As the results of some reserch works and some ignitability tests, the tempreature limits and properties of lieves until they come to ignit were observed.
The critical tempreature limits of leaves are as follows.
Evergreen broad liaved trees 455°C
Decidious broad leaved trees 407°C