日本舶用機関学会誌
Online ISSN : 1884-4758
Print ISSN : 0388-3051
ISSN-L : 0388-3051
主軸駆動発電装置のディジタル化による制御性能の向上と保守の軽減
浅田 一郎堀田 泰弘伊藤 整
著者情報
ジャーナル フリー

1996 年 31 巻 3 号 p. 164-171

詳細
抄録

Various type of shaft driven generating system has been applied on board to save maintenance cost as well as save fuel cost.
The mainstream of such system with large capacity is the one with load commutated inverter system. By adding‘Fault Diagnosis Function’ derived from‘Direct Digital Control’ and‘Graphic Display Function’ utillizing recent micro electronic technology, MTTR (Mean Time To Reopair) has been shortened.
We have developed a Direct Digital Controlled Shaft Driven Generating System that adopts above technology first in japan. Aiming increased Reliability, Availability and Serviceability and delivered the first product in Oct. '95.

著者関連情報
© 社団法人 日本舶用機関学会
前の記事 次の記事
feedback
Top