阪大病院における高力ロリー輸液用微量元素注射剤の調製と品質試験
山路 昭倉田 義昭藤井 康子笠原 伸元紀氏 汎恵大西 昇平岡 栄一
著者情報
ジャーナル フリー

1978 年 4 巻 3 号 p. 120-124

詳細
抄録

At Osaka University Hospital, trace element injections for intravenous hyperalimentation (IVH) were prepared and quality tests were conducted on their content uniformity and sterility. The composition of the injections was: IVH-Zn: Zn 20μmal; IVH-M: Zn 20μmol, Mn 40μmol, Cu 5μmol, I 1μmol. The ingredients were filtrated through 0.45μm membrane filter, filled and wet-sterilized at 121° for 20 minutes. The content uniformity was determined by Atomic Absorption Spectrophotometry. The standard contents of the elements in the injections were determined in the range of 90 to 110w/v%. All lots were negative to Sterility Test (J. P. IX).