The Japanese Journal of Physiology
Print ISSN : 0021-521X
Technical Notes
Implantable Microelectrodes with New Electro-Conductive Materials for Recording Sympathetic Neural Discharge
Kanji MatsukawaHidehiko KomineHirotsugu TsuchimochiJun MurataYoshiharu YonezawaKazuhiko KondoYasuo Seki
著者情報
ジャーナル フリー

2003 年 53 巻 1 号 p. 61-64

詳細
抄録
We have developed two new types of bipolar cuff microelectrodes (volume size, 2–3 mm3) using electro-conductive rubber or water-absorbent polymer, either of which can be applied to measure sympathetic nerve activity in small animals. A renal nerve bundle of an anesthetized rat was inserted into the center hole of the electrode (diameter, 0.15 mm) through a slit and had good contact with the electrodes. Renal sympathetic nerve activity, which was verified by sympathetic ganglionic blockade, could be recorded using either type of implantable cuff electrode.
著者関連情報
© 2003 by The Physiological Society of Japan