日本放射線安全管理学会誌
Online ISSN : 1884-9512
Print ISSN : 1347-1503
ISSN-L : 1347-1503
診断用エックス線装置における遮へい計算評価
越田 吉郎鈴木 昇一能登 公也
著者情報
ジャーナル フリー

2003 年 2 巻 1 号 p. 19-25

詳細
抄録

Using the numerical values in the provisions of the law, the proportion evaluated in the safe side was examined. At the time, the following were examined, whether there is no superfluous protection or underestimation in comparison with NCRP and the Law. The transmission rate using in the 1/10 value layer were higher than that calculated in the half value layer in both lead and concrete. For the leakage in X-ray examination room, the effective doses were estimated to be less than the limit of the controlled area of 1.3m Sv/3 months. However, the dose using the law are 3.3 times in maximum in comparison with the NCRP. In the case of QI (Quality Index) =0.5, it was found that the dose were overestimated in 3.6 times in maximum.

著者関連情報
© 日本放射線安全管理学会
前の記事 次の記事
feedback
Top