実験力学
Print ISSN : 1346-4930
ISSN-L : 1346-4930
Characteristics of Ultrasonic Flowmeter Located Downstream of Elbow
Hideaki MONJITakeshi NAKATANIMasaki SETO
著者情報
ジャーナル フリー

2011 年 11 巻 Special_Issue 号 p. s73-s78

詳細
抄録
Recently, an enough entrance region for a flowmeter cannot be kept in a compact system including fluid machines. In order to know the possibility of such a compact design, the error of an ultrasonic flowmeter was investigated experimentally. In the experiment, the velocity fields downstream of an elbow were measured by PIV and the error was estimated based on the obtained velocity distribution. The error distribution along the pipe and the dependence of the measurement line were obtained. Furthermore, a flow straightener effect was examined.
著者関連情報
© 2011 The Japanese Society for Experimental Mechanics
前の記事 次の記事
feedback
Top