血液と脈管
Online ISSN : 1884-2372
Print ISSN : 0386-9717
心人工弁置換患者における凝血学的指標の検討
フィブリノペプチドAおよび可溶性フィブリンモノマー複合体を中心として
花野 政晴高橋 芳右和泉 徹竹重 富雄滝沢 慎一郎布施 一郎長山 礼三服部 晃柴田 昭大谷 信一江口 昭治
著者情報
ジャーナル フリー

1986 年 17 巻 3 号 p. 242-247

詳細
抄録
In 40 patients with prosthetic heart valves and 3 patients who underwent open mitral commissurotomy, fibrinopeptide A (FPA) and soluble fibrin monomer complex (SFMC) were measured by enzyme immunoassay and fibrin monomer test (FM test), respectively. The relationship between these two parameters and either von Willebrand factor antigen (vWF:Ag), antithrombin III (ATIII) or thrombo-test (TTO) were analyzed.
FPA was elevated in 41.9% and FM test was positive in 25.6% of the patients. High FPA values were obtained frequently in patients with positive FM test. TTO, vWF:Ag and ATIII were not correlated with plasma concentration of FPA. FM test was not correlated with TTO or vWF:Ag, but positive results in FM test were frequently observed in potients with low plasma level of ATIII.
These results indicate that low TTO does not mean suppressed thrombin generation in vivo, and that FPA and FM test would be valuable parameters of hypercoagulability in these patients.
著者関連情報
© 日本血栓止血学会
前の記事 次の記事
feedback
Top