Journal of Neuroendovascular Therapy
Online ISSN : 2186-2494
Print ISSN : 1882-4072
ISSN-L : 1882-4072
TECHNICAL NOTES
One-Way Valve Method for Achieving Effective Flow Reversal on Carotid Artery Stenting
Shinichiro YoshikawaSatoshi IihoshiShigen KasakuraEisuke TsukagoshiShinya Kohyama
著者情報
ジャーナル オープンアクセス

2021 年 15 巻 6 号 p. 404-407

詳細
抄録

Objective: We report a simplified method of manual transfusion with a one-way valve during carotid artery stenting (CAS) with flow reversal.

Case Presentation: A 77-year-old man with cervical internal carotid artery stenosis who developed vulnerable plaques was scheduled for CAS using flow reversal. Blood flow reversal was naturally caused by the arteriovenous pressure gradient, and a method with a one-way valve, which enables simplified manual transfusion using a syringe technique, was used for the patient. CAS was completed without distal embolization.

Conclusion: Manual transfusion can be simplified using a one-way valve in cases of flow reversal during CAS, which often require complicated procedures.

著者関連情報
© 2021 The Japanese Society for Neuroendovascular Therapy

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/