Accuracy of Analytical Treatments for Resonance Absorption in Doppler Resonance Regions
Hideki TAKANOMasayuki NAKAGAWAYukio ISHIGUROSatoru KATSURAGI
著者情報
ジャーナル フリー

1970 年 7 巻 10 号 p. 500-510

詳細
抄録

Resonance shielding factors based on the assumption of constant collision density have been compared with those obtained by solving rigorously the slowing down equation. The results obtained by calculating numerically the flux for this assumption have been thoroughly examined for several compositions and temperatures. This detailed investigation has been based on con-sideration of the interaction effects between neighboring resonances in both the same and different nuclear species. The results obtained have permitted determination of the limits of accuracy obtained with conventional analytical methods. The accuracy of two typical methods of approximation based on the above basic assumption has also been investigated for important Doppler resonance regions in large fast reactor.
The study has covered the resonance regions below 21.5 keV for 238U, and below 10 keV for 235U and 239Pu. It has been found that the results obtained numerically from the assumption of constant collision density are fairly good at higher energies, but the errors become large with decreasing neutron energy and the increasing concentration of fuel. Furthermore the shielding factor and the temperature coefficient of 239Pu are affected considerably by superposition of the resonances of 238U, and the errors are thereby accentuated by a factor of more than two. And the errors resulting from the analytical methods have been found larger than those incurred by the assumption of constant collision density.

著者関連情報

この記事は最新の被引用情報を取得できません。

© the Atomic Energy Society of Japan
前の記事 次の記事
feedback
Top