Digital Period Meter
Seiji INOKUCHITakeshi KOBAYASHIYoshifumi SAKURAIJacques FURET
著者情報
ジャーナル フリー

1971 年 8 巻 10 号 p. 558-562

詳細
抄録
This paper describes a new type of digital reactor period meter utilizing integrated circuits. The period is calculated from the number of counts N2 during t2 at t=τ, where t2 is equal to t1 which is the interval required for N1=104 at t=0. Its output is the digital inverse period signal. The statistical error is delimited by fixing the number of counts instead of the counting interval. The absolute error is about 0.015sec-1 in the case of a delay time of τ=1sec. For τ ?? 2sec, it becomes smaller than 0.008sec-1. The delay time τ is set to a value chosen among 1, 2, 4, 8, 16 and 32sec, depending upon the count rate. The period meter contains about 250 integrated circuits, of which approximately 80 circuits are used for display and auxiliary functions not directly related to the primary purpose of period calculation.