Journal of Oral Science
Online ISSN : 1880-4926
Print ISSN : 1343-4934
ISSN-L : 1343-4934
Original
Effect of different bonding procedures on micro-tensile bond strength between a fiber post and resin-based luting agents
Ying-jie WangOrnella RaffaelliLing ZhangJi-hua ChenMarco Ferrari
著者情報
ジャーナル フリー

2007 年 49 巻 2 号 p. 155-160

詳細
抄録
The purpose of this study was to evaluate the effect of silanization and light-irradiation on bonding between a fiber post and different resin-based luting agents. Sixty silicium fiber posts (Easy Post) were divided into 10 groups according to the type of resin-based luting agent employed, whether the post surface was silanized, whether the adhesive was light-irradiated, and whether Calibra luting agent was used. The micro-tensile bond strength and bonded interface of specimens in each group were evaluated. Specimens luted with Calibra or FluoroCore 2 resin-based luting agent systems were superior to those treated with Multilink or Variolink II, in terms of both bond strength and interfacial integrity. Application of silane, light-irradiation of the adhesive, or light-irradiation of the Calibra resin-based luting agent did not significantly increase the bond strength further. It can be concluded that Calibra or FluoroCore 2 resin-based luting agent systems are more suitable for luting prefabricated Easy Post in a clinical situation, while pre-silanization of the post surface and light-irradiation of XP Bond/SCA adhesive or resin-based luting agent may not be as important as hitherto considered. (J. Oral Sci. 49, 155-160, 2007)
著者関連情報
© 2007 by Nihon University School of Dentistry