Journal of Oral Science
Online ISSN : 1880-4926
Print ISSN : 1343-4934
ISSN-L : 1343-4934
Original
Effect of frequency on the fatigue strength of dentin bonds
Donal D. ScheidelToshiki TakamizawaWayne W. BakmeierRobert L. EricksonAkimasa TsujimotoMasashi Miyazaki
著者情報
ジャーナル フリー

2016 年 58 巻 4 号 p. 539-546

詳細
抄録

This study aimed to investigate the effect of frequency on shear fatigue strength (SFS). The SFS of a resin composite bonded to dentin was determined using three self-etch adhesive systems: G-ænial Bond, Scotchbond Universal, and Optibond XTR. The staircase method of fatigue testing was used to determine the SFS at frequencies of 5, 10, and 20 Hz for 50,000 cycles. The failed bonding sites observed were classified based on the type of bond failure as follows: adhesive failure, cohesive failure in composite, cohesive failure in dentin, or mixed failure (partially adhesive, partially cohesive). A modified t-test with Bonferroni correction was used to analyze the SFS data, and a complex chi-square test was used to analyze the fracture modes. The SFS of OX was significantly greater than that of GB at both 5 and 10 Hz. However, no significant differences in SFS were found among the three frequencies (5, 10, and 20 Hz) in the three self-etch adhesive systems. Furthermore, no significant differences in bond failure mode were observed among the three frequency rates in all the three adhesives used.

(J Oral Sci 58, 539-546, 2016)

著者関連情報
© 2016 by Nihon University School of Dentistry
前の記事 次の記事
feedback
Top