トンネル工学研究発表会論文・報告集
Online ISSN : 1884-9091
ISSN-L : 1345-0832
熱赤外線映像法による覆エコンクリート健全度評価について
杉浦 高広原 享吉田 力皆川 昌樹渡邊 一悟
著者情報
ジャーナル フリー

2003 年 13 巻 p. 359-364

詳細
抄録
The establishment of measuring techniques and the efficiency of thermography judgement for soundness, that is useful for the detection of scaling concrete, has been studied with application to the tunnel lining concrete which has poor temperature changing. It evaluated by the infrared images with active heating and their changing.
The result from the analysis was coincidence with the result from the concrete hitting sound inspection, and operation time would be equivalent to that inspection. By this way, scaling within 50mm depth has been detected. Thermography judgement for soundness is expected as a practicable method with further study and research.
著者関連情報
© 社団法人 土木学会
前の記事 次の記事
feedback
Top