Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Original Articles
Microstructural, mechanical, ionic release and tarnish resistance characterization of porcelain fused to metal Co–Cr alloys manufactured via casting and three different CAD/CAM techniques
Youssef S. Al JabbariXanthippi BarmpagadakiIlias PsarrisSpiros Zinelis
Author information
JOURNAL OPEN ACCESS

2019 Volume 63 Issue 2 Pages 150-156

Details
Abstract

Purpose: To perform a comparative analysis of the microstructure, porosity, mechanical properties, corrosion, and tarnish resistance of Co–Cr alloys prepared by casting and three different computer aided designed/computer aided manufacturing (CAD/CAM) techniques.

Methods: Four groups of metallic specimens were prepared, one each by conventional casting (CST), milling (MIL), selective laser melting (SLM), and milling soft metal (MSM). Ten samples were tested by X-rays, after which their microstructure and elemental composition were tested by scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDX) analysis. Martens hardness (HM) and elastic index (ηIT) were determined by instrumented indentation testing (IIT), while modulus of elasticity (E) was determined by three-point bending. Corrosion measurements were tested according to International Organization for Standardization (ISO) 10271. The electrolytes were analyzed by inductively coupled plasma atomic emission spectroscopy (ICP-AES). The results were analyzed by one-way ANOVA and Holm–Sidak's multiple-comparison test (α = 0.05).

Results: The CST group illustrated internal flaws while all CAD/CAM group samples were found to be free of them. No statistically significant differences were identified among groups in their elemental composition. SLM showed the highest HM, followed by the MIL, CST, and MSM. Elastic index showed significant differences among all groups, with CST showing the lowest and SLM the highest values. SLM showed the highest elastic modulus values, followed by MSM, MIL, and CST. No significant differences were found in ionic release among groups. No surface deterioration after static and cyclic tarnish testing was determined.

Conclusions: The manufacturing procedure significantly affects the microstructure, porosity, and mechanical properties of Co–Cr alloys. In contrast, ionic release and tarnish resistance are independent of the manufacturing technique used.

Content from these authors

This article cannot obtain the latest cited-by information.

© 2019 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution License 4.0 (CCBY 4.0), which allows users to distribute and copy the material in any format so long as attribution is given to the Japan Prosthodontic Society.
https://creativecommons.org/licenses/by/4.0/
Previous article Next article
feedback
Top