Fatigue failure and success rate of lithium disilicate table-tops as a function of cement thickness
Paolo BaldissaraBrunilda KociCarlo MonacoNicola ScottiLorenzo BreschiLeonardo Ciocca
Author information
JOURNAL OPEN ACCESS

2021 Volume 65 Issue 4 Pages 528-534

Details
Abstract

Purpose Under thin, partial coverage restoration the proper cement thickness to be clinically employed still remains an issue. The aim of this study was to determine the failure and success rates of simplified lithium disilicate occlusal veneers as a function of cement thickness. The null hypothesis was that cement thickness has no effect on the fatigue resistance.

Methods Sound human molars were severed in a plane parallel to the occlusal surface to create a flat dentin surface surrounded by enamel edges. Forty-five occlusal veneers 1.0 mm thick (IPS e.max CAD LT) were luted to the teeth with Multilink Automix resin cement, creating 3 experimental groups (n=15) with cement thicknesses of 50, 100, and 200 µm. The restorations were fatigue-cycled using a ball mill machine containing zirconia and stainless steel spheres. Twelve 60 min cycles were performed. Survival statistics were applied to "failure" and "success" events, comparing the three groups using a log-rank Mantel–Cox test and a log-rank test for trends (alpha = 0.05).

Results The failure and success rates were not significantly influenced by cement thickness (P = 0.137 and P = 0.872, respectively); thus, the null hypothesis was accepted. However, when log-rank test for trends was applied to failure events, the tendency to have less failures with increasing thicknesses was found statistically significant (P = 0.047).

Conclusions The cement thickness within the range adopted here did not have a significant effect on the failure or success rate of lithium disilicate occlusal veneers when exposed to randomized impact stresses generating fatigue phenomena.

Content from these authors
© 2021 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution License 4.0 (CCBY 4.0), which allows users to distribute and copy the material in any format so long as attribution is given to the Japan Prosthodontic Society.
https://creativecommons.org/licenses/by/4.0/