Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Original articles
Evaluation of implant-supported connecting crowns fabricated by optical and conventional impression methods
Masahito YokosukaMitsunobu OkamuraHiroshi ShimizuShin-ichi Masumi
Author information
JOURNAL OPEN ACCESS

2021 Volume 65 Issue 4 Pages 461-466

Details
Abstract

Purpose To investigate the accuracy of implant-supported connecting crowns fabricated with digital definitive casts and conventional definitive casts.

Methods Using a master model with two implant bodies inserted into the right mandibular molar area, 10 digital definitive casts were fabricated. Additionally, 10 conventional definitive casts were fabricated. The distance and angle between the two abutments of each definitive cast were compared. To compare the amount of lift of the incisal pin, each of the 10 superstructures was fabricated via computer-aided design/computer-aided manufacturing and then returned to the master model.

Results No significant difference was observed for either the angle or the distance between the two abutments. The amount of lift of the incisal pin when the superstructure obtained via the optical method was returned to the master model was significantly larger than that when the superstructure obtained via the conventional method was returned to the definitive cast and the master model. No significant difference was observed after occlusal adjustment of the superstructures obtained using the conventional method.

Conclusions The precision of definitive casts obtained via the optical method was virtually equal to that of definitive casts obtained via the conventional method. The accuracy of implant-supported connecting crowns fabricated using the optical method was significantly lower than that of implant-supported connecting crowns fabricated using the conventional method. This is attributed to the alignment of the maxillary and mandibular digital definitive casts.

Content from these authors
© 2021 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution License 4.0 (CCBY 4.0), which allows users to distribute and copy the material in any format so long as attribution is given to the Japan Prosthodontic Society.
https://creativecommons.org/licenses/by/4.0/
Previous article Next article
feedback
Top