2026 Volume 70 Issue 3 Pages 383-397
Purpose: Evaluation of the impact of ultraviolet (UV) photofunctionalization on titanium–cement interfaces, specifically its ability to transform titanium into a high-energy surface and enhance crown retention.
Methods: Commercial titanium abutments (standard: 4.0 mm; long: 5.5 mm) were treated with vacuum UV (VUV) light at 172 nm for 1 min. Milled polymethyl methacrylate crowns were cemented using resin-modified glass ionomer cement. Tensile testing quantified the maximum tensile load and interfacial energy. Surface changes were analyzed using contact angle measurements and X-ray photoelectron spectroscopy (XPS). Post-failure interfaces were examined via scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX).
Results: UV-treated standard-length abutments exhibited a 4.1-fold increase in maximum tensile load and 27-fold increase in bonding energy compared with untreated control counterparts. UV-treated long abutments showed a 4.6-fold increase in maximum tensile load and 54-fold increase in bonding energy. UV treatment rendered the titanium surface superhydrophilic and low in carbon, whereas untreated specimens remained carbon-rich and hydrophobic. UV-treated long abutments exhibited 3.1-fold higher energy than UV-treated standard abutments. Notably, long abutments without UV treatment did not outperform standard untreated abutments. SEM and EDX confirmed extensive residual cement on UV-treated abutments, indicating cohesive failure and strong interfacial bonding.
Conclusions: A 1-min UV photofunctionalization transforms titanium into a superhydrophilic, high-energy surface that significantly enhances cement bonding. This physicochemical surface strategy outperforms geometric modifications alone. As a rapid, non-invasive approach, UV photofunctionalization may establish a new standard for durable implant-supported restorations, reducing prosthetic failure and influencing both material selection and clinical and laboratory workflows.