Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958

This article has now been updated. Please use the final version.

Development of dental inspection method: Nondestructive evaluation of an adhesive interface by ACTIVE acoustic emission
Ryoma EzakiAtsushi Mine Kazuhisa SatoKen-ichi FukuiKeigo KumadaMasahiro YumitateShintaro BanAzusa YamanakaMariko MatsumotoBart Van MeerbeekHirokazu MoriyaToshiyuki HashidaHirofumi Yatani
Author information
JOURNAL OPEN ACCESS Advance online publication

Article ID: JPR_D_20_00260

Details
Abstract
Purpose: This study aims to confirm the usefulness of active acoustic emission (Active AE) for reproducible and non-invasive generation of physical external force which is required for conventional AE.
Methods: Experiment 1: A root dentin-resin adhesive interface was observed. The post space was filled with a dual-cure resin composite core material with and without adhesive. The vibration characteristics of the data obtained from the time-frequency analysis were evaluated. Experiment 2: A crown-abutment tooth adhesive interface was observed. Adhesive resin cement was used for luting the crown and adhesion states in the same specimen over time were analyzed with three measurements: at trial-fitting, immediately after luting, and 2 weeks after luting. Data were subjected to time-frequency analysis and relationships between amplitude (indicating loudness) and frequency (indicating the sound component) were analyzed.
Results: Experiment 1: Time-frequency analysis confirmed multiple peak frequencies for each specimen without adhesive and monomodal peak frequency in all specimens using adhesive. Experiment 2: Two weeks after luting, all specimens showed a single major peak except one which showed multiple weak peaks.The three-dimensional visualization of time-frequency analysis revealed one specimen with multiple weak peaks while all others displayed a single, low-amplitude band at 2 weeks after luting.
Conclusions: The state of the adhesive interface can be evaluated using active AE. This basic technique may prove useful to evaluate changes in the adhesive interface of prostheses over time.
Content from these authors

この記事はクリエイティブ・コモンズ [表示 - 非営利 4.0 国際]ライセンスの下に提供されています。
This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BY-NC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.
https://creativecommons.org/licenses/by-nc/4.0/deed.ja
feedback
Top