Journal of Physical Therapy Science
Online ISSN : 2187-5626
Print ISSN : 0915-5287
ISSN-L : 0915-5287
Original Articles
Interrater and Intrarater Reliability of the Active Knee Extension (AKE) Test among Healthy Adults
Mohamad Shariff A HamidMohamed Razif Mohamed AliAshril Yusof
著者情報
ジャーナル フリー

2013 年 25 巻 8 号 p. 957-961

詳細
抄録

[Purpose] The purpose of this study was to determine the reliability of the active knee extension (AKE) test among healthy adults. [Subjects] Fourteen healthy participants (10 men and 4 women) volunteered and gave informed consent. [Methods] Two raters conducted AKE tests independently with the aid of a simple and inexpensive stabilizing apparatus. Each knee was measured twice, and the AKE test was repeated one week later. [Results] The interrater reliability intraclass correlation coefficients (ICC2,1) were 0.87 for the dominant knee and 0.81 for the nondominant knee. In addition, the intrarater (test-retest) reliability ICC3,1 values range between 0.78–0.97 and 0.75–0.84 for raters 1 and 2 respectively. The percentages of agreement within 10° for AKE measurements were 93% for the dominant knee and 79% for the nondominant knee. [Conclusion] The finding suggests the current AKE test showed excellent interrater and intrarater reliability for assessing hamstring flexibility in healthy adults.

著者関連情報
© 2013 by the Society of Physical Therapy Science

This article is distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License.
https://creativecommons.org/licenses/by-nc-nd/4.0/
前の記事 次の記事
feedback