Journal of Physical Therapy Science
Online ISSN : 2187-5626
Print ISSN : 0915-5287
ISSN-L : 0915-5287
Original Article
Reliability and validity of standing balance assessment index using a hand-held dynamometer in stroke patients
Koji IwamotoMasaharu YoshioYuichi TakataNaoki Kozuka
Author information
JOURNAL FREE ACCESS

2016 Volume 28 Issue 11 Pages 3158-3161

Details
Abstract

[Purpose] This study aimed to determine the reliability and validity of our standing balance assessment index using a hand-held dynamometer (the hand-held dynamometer assessment index) in stroke patients. [Subjects and Methods] The participants were 60 stroke patients with impaired standing balance. Intrarater and interrater reliabilities were evaluated employing the intraclass correlation coefficient. Criterion-related validity was evaluated by Spearman’s rank correlation coefficient between the HHD assessment index and the functional balance scale. [Results] The intraclass correlation coefficient values obtained ranged from 0.91 to 0.98, and the correlation coefficient with the FBS was 0.83. [Conclusion] Our findings confirmed the reliability and validity of the hand-held dynamometer assessment index in stroke patients.

Content from these authors
© 2016 by the Society of Physical Therapy Science. Published by IPEC Inc.

This article is distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top