Journal of Radiation Research
Online ISSN : 1349-9157
Print ISSN : 0449-3060
Lung Retention of Pu Following Inhalation of PuO2 in Rats Measured Using a Whole Body Counter
石榑 信人仲野 高志榎本 宏子福田 俊飯田 治三小木曽 洋一佐藤 宏高橋 千太郎山田 裕小泉 彰山田 裕司宮本 勝宏稲葉 次郎
著者情報
ジャーナル フリー

1994 年 35 巻 1 号 p. 16-25

詳細
抄録
A lung retention function on the amount of PuO2 in rats was determined. Five rats were exposed to polydisperse aerosols of PuO2 having a size of 0.47 μm activity median aerodynamic diameter. The initial lung burden was between 1990 Bq and 2960 Bq. Instead of serial-sacrifice study, in vivo counting of low energy L X-rays with thin NaI(Tl) scintillation detectors was used to follow the lung retention of Pu at various intervals up to 468 days after inhalation. The calibration of this counting system was made by measuring lung activity of rats sacrificed for other experimental purposes. It was confirmed that the potential skin contamination and the Pu translocated to the other organs was not counted at the present counting geometry. Our results showed that 77% of PuO2 deposited deep in the lung was cleared with a half-time of 53 days, whereas the residual 23% stayed there for a longer period (a half-time of 795 days).
著者関連情報

この記事は最新の被引用情報を取得できません。

© Japan Radiation Research Society
前の記事 次の記事
feedback
Top