International Journal of Automotive Engineering
Online ISSN : 2185-0992
Print ISSN : 2185-0984
ISSN-L : 2185-0992
研究論文
Analysis of the Internal Flow Structure of Torque Converter Using Proper Orthogonal Decomposition under Transient Driving Conditions
Yasunori KunisakiShigeru MurataYohsuke Tanaka
著者情報
ジャーナル オープンアクセス

2020 年 11 巻 4 号 p. 169-176

詳細
抄録
The characteristic structure of the flow field in a torque converter is quantitatively evaluated using proper orthogonal decomposition (POD) under transient driving conditions assuming start-up acceleration and deceleration of a vehicle. The time-series velocity data inside the torque converter to be input to POD is measured using a particle image velocimetry (PIV) technique. At first, in the case of changing the rotational speed of the impeller or turbine, dynamic cascades with changing rotational speed were observed to induce fluid motion. The flow field structure was gradually reformed according to the speed ratio after transition. In addition, the region of structural changes of the flow field was found to be larger for the decelerating driving condition compared to the case of start-up acceleration.
著者関連情報
© 2020 Society of Automotive Engineers of Japan, Inc

This article is licensed under a Creative Commons [Attribution-NonCommercial-ShareAlike 4.0 International] license.