立体形状試験体における全方向傷の磁粉探傷試験を目的とした磁化装置の検討
福岡 克弘野間 翔太小林 正樹尾崎 智裕及川 芳朗
著者情報
ジャーナル フリー

2016 年 24 巻 3 号 p. 155-160

詳細
抄録

Mechanical parts, plants and cross-linkages inspected with MT are typically complex 3D shapes. In the complex 3D shape portion, because a magnetizer often cannot be configured to the inspection portion and the test object cannot be appropriately magnetized, there is a possibility of overlooking a crack in such an instance. Thus, MT system development that was successfully able to detect omnidirectional cracks in 3D shape portions was considered in this study's trials. Two magnetizers were hence arranged face-to-face, and the magnetization of omnidirectional scenarios for all surfaces of 3D shape test object (arranged in between both magnetizers) was evaluated.