キャビテーション下での光ファイバプローブハイドロホンを用いた超音波洗浄機の絶対音圧測定に関する検討
市川 将稔千島 一輝小池 義和
著者情報
ジャーナル フリー

2018 年 26 巻 1 号 p. 139-144

詳細
抄録

 Authors investigated whether the absolute sound pressure in the ultrasonic cleaning machine can be measured by fiber optic probe hydrophone (FOPH) under cavitation. Since the intensity on the cavitation bubble collapse is high in the frequency range of about 30 to 100 kHz, the sound pressure measurement using FOPH was applied to ultrasonic cleaning machine with the use of a submerged ultrasonic transducer with frequency of 35.5 kHz. In the case of cavitation bubble collapse occurs frequently, it is confirmed that fundamental and harmonic components can be measured by FOPH. And also, the sound pressure distribution was compared to the analysis result using finite element method.