日本AEM学会誌
Online ISSN : 2187-9257
Print ISSN : 0919-4452
ISSN-L : 0919-4452
[学術論文]
連続波とパルス波の電磁超音波共鳴法による配管減肉検査の比較
孫 宏君浦山 良一小島 史男橋本 光男内一 哲哉高木 敏行DOBMANN Gerd
著者情報
ジャーナル フリー

2018 年 26 巻 2 号 p. 312-319

詳細
抄録

 This paper describes the measurement of wall thinning by continuous wave electromagnetic acoustic resonance (CW-EMAR) and pulse wave electromagnetic acoustic resonance (PW-EMAR). Simulated pipe wall thinning specimens are measured. The two methods show accurate results in the areas with a low variation of thickness, and the accuracy decreases when the thickness changes drastically. The two methods are analyzed by using the finite element method. The results show that with the increase of the bottom inclination, the accuracy of the two methods is reduced. For thin specimens, the reason for the larger error of CW-EMAR method is due to that CW-EMAR method is more easily affected by ultrasonic scattering and nonuniform distribution of static magnetic field.

著者関連情報
© 2018 日本AEM学会
前の記事 次の記事
feedback