日本AEM学会誌
Online ISSN : 2187-9257
Print ISSN : 0919-4452
ISSN-L : 0919-4452
[学術論文]
磁性金属板判別のための空心円形コイルのサイズ検討
藤田 竜司木村 藤一郎二俣 昌樹田代 晋久脇若 弘之中村 善宏田中 伸幸齋藤 脩平
著者情報
ジャーナル フリー

2018 年 26 巻 2 号 p. 320-325

詳細
抄録

 An eddy current method is a method for discriminating metals nondestructive and noncontact. It is very important to know the changes in the frequency profile of sensor coil inductance. If an air-core coil is placed to face an iron plate, the changes contain both the conductivity and permeability information. In order to find a suitable coil size, the same values of in inductance are designed for four coils which have different diameter to generate same magnetic flux at a constant current. The frequency profiles are measured with a conventional impedance analyzer, as a function of distance between the coil and metal plate. The measured values are as same as 200 μH for four coils until a few hundred Hz. When the coils are placed to face the metal, a decrease in lift off produces an increase in inductance at low frequency, and a decrease in inductance at high frequency. There is a cross frequency at which the measured value is as same as inductance of coil only. It is found that it seems to be defined by the coil diameter, not defined by the liftoff. Introducing normalized parameters, other useful considerations are also noted.

著者関連情報
© 2018 日本AEM学会
前の記事 次の記事
feedback
Top