人工臓器
Online ISSN : 1883-6097
Print ISSN : 0300-0818
ISSN-L : 0300-0818
Double Filtration Plasmapheresis用自動血漿分画分離装置の開発
江良 和雄阿岸 鉄三金子 岩和蓮尾 良博葛西 浩美久保 和雄鈴木 利昭太田 和夫杉野 信博安部 道夫
著者情報
ジャーナル フリー

1982 年 11 巻 1 号 p. 95-97

詳細
抄録
Double filtration plasmapheresis was devised in an attempt to reduce an amount of replacement fluid and consequently to save human blood products. Clinical effectiveness and conservation of human blood.
However, as balancing manipulation of three pumps for an extracorporeal circulation, plasma separation and plasma filtration was cumbersome, an automatic control system which automatically regulates a plasma separation rate has been devised.
With this new system double filtration plasmapheresis has become performed very easily with less hemolysis.
著者関連情報
© 一般社団法人 日本人工臓器学会