Jinko Zoki
Online ISSN : 1883-6097
Print ISSN : 0300-0818
ISSN-L : 0300-0818
Tracheal Reconstruction Using Collagen-Plastic Composites
-second report-
Y. MIYAMOTOY. SHIMIZUS. MATSUNOBEH. KATOT. TERAMATSUS. OKAMURAT. HINOY. SHIBATA
Author information
JOURNAL FREE ACCESS

1979 Volume 8 Issue 1 Pages 78-80

Details
Abstract
We reconstruct the dog trachea with the composite of collagen and Marlex high density mesh. The supporting consistency of this mesh is sufficient enough to prevent air way collapse. Since the regeneration of the epithelium progresses from the cut ends, long replacement may be more easy than the wide one. Physiological function of the reconstructed trachea was examined by means of cine-bronchogram and endoscopic observation of the expectoration of India ink. Even on the six months after operation, both the tracheal contractility and mucociliary transport were impeded to some extent, but in clinically, which seemed to be out of hindrance.
Content from these authors
© The Japanese Society for Artificial Organs
Previous article Next article
feedback
Top