Journal of Advanced Science
Online ISSN : 1881-3917
Print ISSN : 0915-5651
ISSN-L : 0915-5651
Paper
Fatigue measurement of a shape memory Ti-Ni-Cu wire used as artificial heart muscle
R. IBUKIG. GUENINM. MORINS. MARUYAMA
著者情報
ジャーナル フリー

2005 年 17 巻 1+2 号 p. 38-41

詳細
抄録

Influence of fatigue on shape memory effect in Ni-Ti-Cu wires was quantitatively evaluated. Strain and variation of transformation points was measured under constant tensile load. Transformation points depending on cycle numbers of SMA wire specimen decrease until 1000 thermal cycles and length of the sample at high and low temperature increases when the number of thermal cycles increases.

著者関連情報
© 2005 Society of Advanced Science
前の記事 次の記事
feedback
Top