Japanese Journal of Clinical Chemistry
Online ISSN : 2187-4077
Print ISSN : 0370-5633
ISSN-L : 0370-5633
An Approach to Clinical Test of Mini-Column Chromatography with DEAE-Sephadex A-50 II. Determination of GOTm in Human Serum
ISAO ISHIGUROYOICHI NAGAMURANAOMICHI OGITSUTAKAAKI OOTSUKIRIKIO SHINOHARA
Author information
JOURNAL FREE ACCESS

1977 Volume 5 Issue 2 Pages 163-169

Details
Abstract

A new mini-column method, which we devised previously for determination of IgG, was used for quantitative determination of the enzyme activities of GOTm in human serum. When 50μl of serum was applied to this mini-column with DEAE-Sephadex A-50, GOTm was not adosorbed and eluted rapidly. The caliblation curve of purified human GOTm was determined with Karmen's, Babson's and Reitman-Frankel method, and Karmen's method was the best one of these method. When several sera with addition of purified GOTm was applied to this column, GOTm was recovered about 100% in eluate. The correlation of this method and electrophoresis method was well at low activity of GOTm, but not well at high activity of GOTm by the reason why electrophoresis method can not determined GOTm accuratly. The correlation of this method and immunoadsorbance method was very well. This method thus appeares to be useful in daily clinical test.

Content from these authors