高速液体クロマトグラフィーによるヒト尿中VMA, HVAおよび5-HIAAの同時定量
柴戸 光子後藤 潮黒田 吉男荒川 規矩男
著者情報
ジャーナル フリー

1977 年 5 巻 4 号 p. 385-390

詳細
抄録
A simultaneous determination of urine VMA and HVA, as well as 5-HIAA was attempted by highspeed liquid chromatography.
Urine was acidified with 6 N hydrochloric acid and extracted with ethyl acetate. The ethyl acetate layer was evaporated to dryness under reduced pressure. The residue was dissolved in 0.2 N acetic acid, and 40μl of the aliquot was injected on to the column.
A highspeed liquid chromatograph was assembled from Waters ALC/GPC204 Type, the model 660 soovent programmer and packed with μBondapack C18. The mobile phase was consisted of water and methanol solution of PIC-B7. Elution was done gradiently by from 15 to 30% methanol in 10 minutes.
The value of VMA was well correlated to that obtained colorimetrically. Moreover, the method proved to be very specific, reproducible with a good recovery.
The technique was applied to the 10 urine specimens of normal subjects. The mean excretion of VMA was3.5±1.1 S. D. mg/day, 5-HIAA 3.3±1.3 S.D. mg/day and HVA 8.7±2.4 S.D. mg/day. In a case of phaeochromocytoma,they were 15.2mg/day, 6.2mg/day and 19.0mg/day respectively.
Thus the method issimple and accurate enough for a routine simultaneous determination of urine VMA, HVA as well as 5-HIAA.